Home > Products > UPS power supply

Solar PV inverter

Brand: RENDA
Model: RD500
Updated: 2015/10/29
  • Product description
  • Scope of application
  • Product features
  • Technical parameters

Photovoltaic inverter is an inverter used in solar photovoltaic power generation system and is an important component of photovoltaic system.

Photovoltaic inverters are mainly used in the field of photovoltaic power generation.

product features

● The controller module is controlled by M P P T and the maximum conversion efficiency is as high as 9 7 %.

●modular design, Strong compatibility and easy maintenance

● adopt digital control strategy , the whole machine control is flexible and accurate

● Perfect protection and alarm functions , which makes the system have high reliability

●The output adopts power frequency transformer isolated output , high security, high reliability

●Intelligent artificial interface , which can visually display various parameter information of the product

●Rich menus, Easy to upgrade and expand.

automatic operation and shutdown function

after sunrise in the morning, the solar radiation intensity gradually increases, and the output of the solar cell also increases, and when the output power required for the inverter to work is reached, the inverter automatically starts to operate. After entering operation, the inverter will monitor the output of the solar cell module at all times, as long as the output power of the solar cell module is greater than the output power required for the inverter to work, the inverter will continue to run until sunset shutdown, even on rainy days the inverter can operate. When the output of the solar cell module becomes smaller and the output of the inverter approaches 0, the inverter forms a standby state.

maximum power tracking control function

the output of the solar cell module varies with the intensity of solar radiation and the temperature of the solar cell module itself (chip temperature). In addition, since solar cell modules have the characteristic that the voltage decreases with the increase of current, there is an optimal operating point to obtain the maximum power. The intensity of solar radiation varies, and obviously the optimal operating point is also changing. Relative to these changes, the operating point of the solar cell module is always at the maximum power point, and the system always obtains the maximum power output from the solar cell module, this control is the maximum power tracking control. The biggest feature of inverters for solar power generation systems is that they include the function of maximum power point tracking (M P P T ).

solar PV inverter (technical  parameters )

 Model No.

RD500

RD1000

RD1500

Rated capacity

500W

1000W

1500W

Inverter mode

PV input voltage range

33-60Vdc

Rated battery voltage

24Vdc

Battery float voltage

27.2Vdc

Rated output voltage (V)

220Vac

Rated output frequency (Hz)

50Hz±1Hz

Output voltage range

±2%Vrms

Output current

2.27A

4.54A

6.8A

Output voltage waveform distortion

Less than or equal to 2%

Efficiency

More than 80%

Controller efficiency

Greater than 955

Quiescent current

Less than or equal to 3% Irms

The peak factor

3

Overload protection

When 125% overload, the output is disconnected after 60 seconds; When 150% overloaded, disconnect the output after 10 seconds

Switching time

Less than 3ms

Mains mode

Mains input voltage range

220V±10%Vac

Mains input frequency

50Hz±1Hz

System parameters

Display mode

LCD+LED

Display content

Electrical measurement, battery capacity, input voltage, output voltage, load, temperature

Communication

RS232+RS485 (communication function optional)

Cooling method

Intelligent air-cooled

Protection function

High voltage, undervoltage, overfrequency, underfrequency, short circuit, overcharge,

overdischarge, overtemperature, overload protection

Isolation method

Power frequency transformer

Ambient temperature

-10℃-50℃

Ambient humidity

Less than or equal to 93% (non-condensing)

Noise

Less than 60dB

Altitude Less than or equal to 1000m

, greater than 1000m to reduce the capacity of

? 1991-2025 Renda Group All Rights Reserved.  粵ICP備12015448號  
免费国产午夜视频在线观看,欧美动漫一区二区免费,久久一区二区三区网站,欧美毛多水多肥妇欧洲少妇
亚洲国产综合精品2021 | 在线观看肉丝少妇被日字幕 | 日韩AV变态在线观看 | 一级a一片久久久精品网络 久久国产精品系列 | 亚洲综合久久综合网 | 中文字幕在线视频观看网站 |